Home › Guides › Wiring and electrical safety

Dryer and stove outlets

The dryer outlet and the stove outlet: their shape, their rating, what Québec’s Code asks for, and what to do when the cord doesn’t fit.

Get a quote

By the master electricians of STM-ÉlectriqueRBQ licence 5815-0137-01Sources checked on October 30, 2026

In short

This guide covers the big 240 V outlets in the home: the dryer outlet and the stove outlet.

  • In the 2018 edition of the Code, an electric dryer over 1,500 W at 115 V and up to 30 A plugs into a 14-30R receptacle.
  • A free-standing electric range of up to 50 A plugs into a 14-50R receptacle (2018 edition).
  • For its GEW1500RL0 dryer sold in Canada, the manufacturer Whirlpool calls for a grounded 4-prong outlet, type 14-30R.
  • If that dryer’s cord doesn’t fit, Whirlpool says not to modify the plug and to have the proper outlet installed by a qualified electrician.
Jump to a section6
  1. The dryer outlet
  2. The stove outlet
  3. The cord doesn’t fit
  4. What not to do
  5. What we do
  6. Frequently asked questions

The dryer outlet

According to the Régie du bâtiment du Québec’s guide (2018 edition of the Code), the outlet of an electric dryer over 1,500 W at 115 V and up to 30 A has a CSA 14-30R configuration.

The bonding conductor connects to the screw provided for it on that outlet (2018 edition).

An electric dryer counts as a continuous load, and its outlet is protected by a breaker or fuses rated no higher than the outlet (2018 edition).

The stove outlet

A free-standing electric range with a demand load of up to 50 A plugs into a 14-50R receptacle, which a branch circuit of at least 40 A can supply (2018 edition).

Its outlet is protected by a breaker or fuses rated no higher than the outlet (2018 edition).

Its height is set by the Code (2018 edition): the details are in Dedicated circuits: which appliances need one?.

DryerStove
Outlet14-30R14-50R
RatingUp to 30 AUp to 50 A (demand load)
What the Code asks for14-30R configuration, bonding at the outlet’s screw14-50R receptacle, branch circuit of at least 40 A
Edition20182018

The cord doesn’t fit

If the cord doesn’t fit: for its GEW1500RL0 dryer sold in Canada, the manufacturer Whirlpool is clear:

  • don’t modify the plug supplied with the dryer;
  • don’t use an extension cord;
  • have the proper outlet installed by a qualified electrician.

For that dryer, it’s the outlet that changes, not the plug, and that job goes to an electrical contractor.

What not to do

Never plug a portable generator into a dryer outlet with a double-male cord: see Generator transfer switch: the heart of the job.

For its GEW1500RL0 dryer, the manufacturer Whirlpool says not to use an extension cord.

The cord doesn’t fit?

We install the outlet that matches the appliance’s plug, with its circuit if needed. The price is in the quote.

Send my quote request

What we do

240 V outlets and circuits are part of the general electrical work we do every day.

Before adding a circuit, we check that the panel can take it: see Is 100 amp service enough?.

Frequently asked questions

Is a dryer 30 or 50 amps?

In the 2018 edition of the Code, an electric dryer of up to 30 A plugs into a 14-30R receptacle. The 14-50R receptacle is for a free-standing electric range of up to 50 A.

220 or 240 volts?

In Québec, Hydro-Québec supplies homes at 120/240 V: ordinary outlets are 120 V; the range and the dryer are 240 V. Some existing buildings are at 120/208 V instead.

Can I change the cord instead of the outlet?

For its GEW1500RL0 dryer, the manufacturer Whirlpool says not to modify the supplied plug and to have the proper outlet installed by a qualified electrician. For another appliance, follow its manual.

Can a dryer be plugged in with an extension cord?

Not the GEW1500RL0 dryer: its manufacturer, Whirlpool, says not to use an extension cord. For another appliance, follow its manual.

A new dryer or stove to connect?

We install 240 V outlets and circuits; the exact price is in the quote.

4.9 from 469 Google reviews · RBQ licence 5815-0137-01 · CMEQ members · Free detailed quote

Get a quote: dryer or stove outlet

EN - Service request (English service pages)