Breaker keeps tripping: causes and what to do
Overload, short circuit, ground fault, arc fault or a worn breaker: how to look for the cause, what you are allowed to do yourself in Québec, and when it’s time to call an electrician.
In short
- A breaker that trips is doing its job: it cuts the power when it sees an overload or a fault.
- Four causes come up: overload, short circuit, ground fault and arc fault. The breaker itself can also be the problem.
- You can reset a breaker and press TEST. In Québec, any work on the wiring itself (breaker, outlet, wires) is an electrician’s job, even in your own home.
- A breaker that trips again as soon as you reset it, even with everything unplugged, should not be reset over and over: call an electrician.
- Breakers are not interchangeable between panel brands.
In this guide
The first instinct is to flip it back on and move on. But a breaker that keeps tripping is telling you something, and this guide helps you understand what.
Why does my breaker keep tripping?
Three questions to find the likely cause and know what to do, safely.
First: do you notice any of these signs?
- burning or rubber smell
- outlet or panel that is hot, discoloured or crackling
- sparks at an outlet
- tingling when you touch an appliance
- water on the panel or the breaker
What a breaker does
Hydro-Québec sums it up: the breakers in your panel automatically cut the power when there is an overload or another fault. They protect the wiring from overheating, and so the house from fire. When a breaker trips, it is reacting to something on the circuit, or it is faulty itself: the table below covers both.
The causes, and what they mean
Schneider Electric, a breaker manufacturer, lists four causes of tripping. The breaker itself and its connections can be a fifth:
| Cause | What is happening |
|---|---|
| Overload | The circuit is drawing more than it is rated for. |
| Short circuit | A fault in the wiring or in an appliance. |
| Ground fault | Current is leaking to ground. Outlets protected by a GFCI cut the power on this kind of leak. |
| Arc fault | An arc in the wiring or in an appliance. Arc-fault breakers cut the power on this kind of fault. |
| Faulty breaker or connection | The breaker itself is defective, or it makes poor contact with the panel. |
Poor contact between a breaker and the panel’s bus bar is not a small thing: British Columbia’s safety authority documented a panel fire very likely caused by exactly that kind of poor contact. That is one reason a breaker that feels hot or smells burnt should not be reset: call an electrician.
What to do, step by step
- Unplug or switch off the appliances on the circuit that tripped.
- Reset the breaker: push the handle fully to OFF, then back to ON, as the manufacturers instruct.
- Plug things back in one at a time. If the breaker trips when you plug in a specific appliance, you have probably found the culprit: have it checked or replace it.
- If it is an arc-fault or GFCI breaker (it has a TEST button), press TEST: it should trip. If it doesn’t, have it checked by an electrician.
- Stop there. If you still can’t find the cause, it’s time to call an electrician. Schneider Electric says it plainly: when the cause is a plugged-in appliance, an electrician may not always be able to find it, which is why step 3 matters.
When to call right away
We recommend calling an electrician without waiting if:
- The breaker trips as soon as you reset it, even with everything unplugged.
- You smell burning, hear crackling, or the breaker or an outlet feels hot.
- It is always the same circuit, with no appliance to blame.
- It started after some work: an outlet added, a light fixture changed.
- It is the main breaker that trips.
A breaker that keeps tripping?
We look for the cause instead of working around the protection, and the price is in writing before any work starts.
Request a quoteWhat the law allows in Québec
Resetting a breaker and pressing its TEST button: no rule forbids it, and manufacturers teach homeowners to do it. Everything else is different, and it isn’t a question of skill. Québec’s building authority, the Régie du bâtiment, is clear: a person may not do work on an electrical installation, even in their own home, without the proper licence. Replacing a breaker, an outlet or a light fixture is electrical work.
Under Québec law, breaking the Master Electricians Act and the Building Act can bring a fine of $5,000 to $200,888.
Corporation des maîtres électriciens du Québec (paraphrased from French)
Arc-fault and GFCI breakers
These breakers watch for more than an ordinary breaker does, so they trip for other reasons too. For arc-fault breakers, the manufacturer Siemens lists, among others:
- a shared neutral between two circuits;
- a neutral that is poorly connected, at the breaker or at the appliance;
- a neutral touching ground somewhere on the circuit;
- a real arc, in the wiring or in an appliance.
These are wiring corrections, for an electrician. Since the 2018 code, Québec has required arc-fault protection on almost every 120 V outlet circuit in a home, not just in bedrooms. The code does not require changing existing circuits that are not being worked on. Our guide on arc-fault breakers (in French) explains where it is required.
Replacing a breaker
A breaker can wear out. Schneider Electric puts the life of a breaker at about 30 years, in good conditions and with regular maintenance. When one is replaced, one rule matters more than price: only a breaker approved for that brand and model of panel goes in. Breakers are not interchangeable between brands. In the fire documented in British Columbia, the breaker was from a different brand than the panel.
The panel brand we install most often is Siemens, with its own breakers.
If you are running out of circuits, or if it is the main breaker that trips, the question may be the capacity of your electrical service. Our guide is 100 amp service enough? explains how that is checked.
Have your breaker checked
Your answers are attached to the request automatically. For an emergency, call 438 542-7304 instead, 24/7.
Frequently asked questions
Should I be worried if my breaker keeps tripping?
A trip means the breaker reacted to something. If it trips as soon as you reset it, feels hot, smells burnt, or keeps tripping on the same circuit with no appliance to blame, call an electrician.
How many times can a breaker trip before it goes bad?
We found no official number. Schneider Electric puts the life of a breaker at about 30 years in good conditions. A breaker that trips with no cause, or feels hot to the touch, should be checked by an electrician.
What makes a breaker trip again right after it is reset?
The cause may still be there: an appliance still plugged in, a short circuit or a ground fault on the circuit, or a faulty breaker. Unplug everything and reset once. If it trips again with nothing plugged in, stop and call an electrician.
Why does it trip when I turn on the space heater?
That is what an overload typically looks like: the heater adds to what is already running on the same circuit, and the total goes over its rating. Plug it into another circuit. If it keeps happening, an electrician can add a circuit.
Can I replace a breaker myself?
No. According to the Régie du bâtiment, any work on an electrical installation, even in your own home, must be done by a contractor with the proper licence. And the breaker must be approved for your specific panel.
The main breaker tripped: what do I do?
First check whether the whole street is out: if so, it is a Hydro-Québec outage. If it really is your main breaker that tripped, don’t keep resetting it: call an electrician.
How much does it cost to find the cause?
It depends on what we find: a faulty appliance, a connection to redo, a breaker to replace, or a circuit to add. We explain the cause, and the price is in writing before any work starts.
A breaker that trips and you can’t tell why?
We look for the cause instead of working around the protection, and we explain what we fix. Free detailed quote.
4.9 from 469 Google reviews · RBQ licence 5815-0137-01 · CMEQ members · Free detailed quote
Sources
The figures and requirements in this guide come from the documents below, checked on October 4, 2026.
- Hydro-Québec: the electrical panel (in French)
- RBQ: work you can do yourself (in French)
- CMEQ: a licence is mandatory (in French)
- CMEQ: arc-fault protection in the 2018 code (in French)
- Schneider Electric: The Safer Home (causes of tripping)
- Schneider Electric Canada: breaker service life
- Siemens: arc-fault breaker tripping
- Technical Safety BC: incident report, breaker from another brand than the panel